official distributor for Bulgaria

Dimension EXL 200 Integrated Chemistry System

Simplify your operations with an integrated clinical chemistry and immunoassay analyzer.

The Dimension® EXL™ 200 Integrated Chemistry System, now including Dimension Remote Services and enhanced QCC PowerPak®, gives you the power of both chemistry and immunoassay testing in a compact system ideal for smaller-sized laboratories.

  • Offers the versatility to deliver better outcomes in any location with a comprehensive menu, including critical cardiac assays and our automated-pretreatment immunosuppressive drug assays.
  • Transition easily and correlate results between core and satellite labs using the partnership of the Atellica® Solution and the Dimension EXL 200 Integrated Chemistry System.
  • Improve workflow efficiency with the ability to test any tube, any place, any time with no-pause loading, no tube sorting, no splitting tubes, and no shuttling between analyzers.

Dimension EXL 200 Integrated Chemistry System

Consolidate chemistry and immunoassay testing with one system small enough to fit in any laboratory.

True Companion to the
Atellica Solution

Inspired by the Atellica Solution , new design elements, remote service, security features, and assay correlations make this a true companion for your smaller-sized laboratory.

Support Patient Care

Gain the flexibility to run a wide variety of tests, including chemistry, immunosuppressive drug, STAT and immunoassays, in one small footprint

True Integration for Increased Efficiency

  • Consolidate testing with a comprehensive menu, including chemistry, cardiac, thyroid, and our automated-pretreatment immunosuppressive drug assays.
  • Avoid splitting samples—simultaneously run all assays from one sample tube.
  • Simplify your workflow—mix and match chemistry and immunoassay tests on the fly in one common reagent area.
  • Save space with a compact footprint of 1.5 sq m (16.2 sq ft).

LOCI Technology Inside

  • Experience excellent immunoassay sensitivity using small sample volumes with homogeneous LOCI® Advanced Chemiluminescence Technology.
  • Produce fast and accurate results—assay times as short as
    10 minutes for key critical assays.

High Productivity

  • Respond quickly with STAT sampling from any position, a
    4-minute time to first result for a basic panel, and electrolyte results in under a minute.
  • Enhanced QCC PowerPak offers even more automated dilution, calibration, control, alert, and system-check features.
  • Save time with no manual sample pretreatment, no manual reagent preparation, and long calibration stability.
  • Keep systems operating with only 5 minutes of daily maintenance, no daily hands-on maintenance for electrolytes, and the new Dimension Remote Services feature to manage requests when service is needed.
  • Further simplify laboratory operations with connectivity to Siemens Healthineers automation and IT solutions.
Anemia
Ferritin
Folate
Vitamin B12
Vitamin D Total
BNP
CKMB Mass
CKMB Activity
CardioPhase® hsCRP
Myoglobin
NT-proBNP
High-Sensitivity Troponin I
Fructosamine
Hemoglobin A1c
Acetaminophen
6-Acetylmorphine (6-AM)
Amphetamines
Barbiturates, Urine
Barbiturates, Serum
Benzodiazepines, Urine
Benzodiazepines, Serum
Buprenorphine
Cannabinoids (THC)
Cocaine Metabolite
Ecstasy
EDDP (Methadone Metabolite)
Ethyl Alcohol
Ethyl Glucuronide (EtG)
Fentanyl
Methadone
Methaqualone
Opiates
Phencyclidine
Propoxyphene
Salicylate
Tramadol
Tricyclic Antidepressants
Acid Phosphatase
Alanine Aminotransferase (ALT)
Albumin (BCP)
Aldolase
Alkaline Phosphatase (ALP)
Ammonia
Amylase
Aspartate Aminotransferase
Bilirubin, Direct
Bilirubin, Total
Calcium (CPC)
Carbon Dioxide
Chloride
Cholesterol
Creatine Kinase
Creatinine
Creatinine (Enzymatic)
Dibucaine Number
Gamma Glutamyltransferase (GGT)
Glucose
Glucose, Hemolyzed
HDL Cholesterol
Iron
Lactate
Lactate Dehydrogenase
LDL Cholesterol
Lipase
Magnesium
Microalbumin
Pancreatic Amylase
Phosphorus
Potassium
Pseudocholinesterase
Sodium
Total Iron Binding Capacity
Total Protein
Total Protein, CSF/Urine
Triglycerides
Urea Nitrogen (BUN)
Uric Acid
Cyclosporine
Cyclosporine (Extended Range)
Everolimus
Mycophenolic Acid
Sirolimus
Tacrolimus
Free PSA
Total PSA
hCG
Procalcitonin (PCT)
SARS-COV-2 IgG
SARS-COV-2 Total
α1-Acid Glycoprotein
β-2 Microglobulin Latex
Antistreptolysin O (ASO)
Apolipoprotein A-I
Apolipoprotein B
Ceruloplasmin
Complement C3
Complement C4
CRP
CRP, Extended Range
Haptoglobin
Ig Light Chains, Type Kappa
Ig Light Chains, Type Lambda
Immunoglobulin A
Immunoglobulin G
Immunoglobulin M
Lipoprotein (a) Ultra
Prealbumin
Rheumatoid Factor (RF)
Transferrin
Amikacin
Caffeine
Carbamazepine
Digitoxin
Digoxin
Ethosuximide
Gentamicin
Lamotrigine
Levetiracetam
Lidocaine
Lithium
Methotrexate
N-Acetylprocainamide (NAPA)
Phenobarbital
Phenytoin
Procainamide
Theophylline
Tobramycin
Valproic Acid
Vancomycin
Free T3
Free T4
T Uptake
Total T4
TSH

Product Specifications

System Description

Random-access clinical chemistry and immunoassay system with LOCI® chemiluminescence technology

Test Throughput

Up to 440 photometric tests, 187 IMT tests and 167 immunoassay tests per hour

Assay Time (From Aspiration to Result)

IMT (Na, K, Cl) <1 min; BMP (Na, K, Cl, CO2, GLU, BUN, CREA) 4 min; TNIH 10 min; HCG 14 min

Assays Onboard

47, including 3 QuikLYTE® IMT

Sample Handling

Validated Sample Types

Serum, plasma, urine, cerebrospinal fluid, whole blood (varies by assay)

Sample Tubes

5 mL, 7 mL, 10 mL tubes; 1.5 mL sample cups; 1 mL small sample containers; pediatric tubes

Sample Bar Codes

Code 39; Code 128; Codabar (USS); Interleaved 2 of 5 with or without check digit, 12 digits maximum

Sample Wheel

60 sample positions in six 10-tube segments; positive sample identification

STAT Handling

No dedicated positions; STAT samples are processed with priority

Sample Integrity Control

Liquid-level sensing; clot, bubble and short-sample detection and management; hemolysis, icterus,and lipemia checks

Auto-Repeat

Automatic repeat testing from the original sample

Sample Volume Per Test

2–60 µL (varies by assay)

Sample Dilution

Automatic dilution: 1:1.5 up to 1:200

Auto-Reflex Testing

Will automatically perform additional tests based on results of first test

Sample Carryover Prevention

Automated wash protocols and single-use cuvettes help minimize carryover

Reaction Area

Reaction Cuvettes

Onboard capacity of 12,000 formed cuvettes

Reaction Bath

Air; incubation temperature 37°C

Path Length

0.5 cm ±0.0125 cm

Photometer

Optical filter wheel provides wavelengths of 293, 340, 383, 405, 452, 510, 540, 577, 600, and 700 nm

Light Source

Standard tungsten halogen lamp, operation at 6.5A (6.8v)

Reaction Times

1-32 minutes (varies by assay)

Automatic Correction

Serum blank, cell blank, reagent blank, measurement point change, autodilution

Assay Technologies

LOCI, heterogeneous immunoassay, PETINIA and ACMIA, photometry, potentiometry (IMT), turbidimetric, and Emit®

Assay Result Calculations

Endpoint, rate, multipoint

Reagent Handling

Reagent Compartment

44 positions, refrigerated between 2–8°C (36–47°F)

Dispensing System

2 probes with liquid-level sensing

Reagent Cartridges

Flex® Reagent Cartridges, bar coded, 15 to 360 tests/Flex (varies by assay)

Average Total Reaction Volume

350–500 μL per test (varies by assay)

Reagent Integrity Control

Bar-code reagent identification; automatic inventory tracking and flagging;
Calibration and control validity tracking and flagging;
Reagent onboard tracking of tests remaining, lot number, onboard stability, and expiration date

Onboard Stability

Up to 42 days (varies by assay)

Test Capacity Onboard

25,200 tests average;

33,300 tests maximum

Open-system Capability

Channels

110 assay channels; includes 15 open channels for user-defined applications

Integrated Multisensor Technology (IMT) for Na+, K+, Cl

QuikLYTE IMT

Indirect simultaneous measurement of Na+, K+, Cl

Sample Volume

40 μL for all three tests

Automated Operation

Automatic priming cycle, no user calibration, automatic urine dilution 1:10

Cartridge Expected Use Life

1000 samples or 5 days, whichever comes first

Calibration/QC

Validated Calibration Interval

Up to 90 days, tracked by software

Auto-calibration

Assay-specific time interval or with new reagent lot

Auto-QC

User-defined time interval

Calibration Review

Graphical display of calibration curves

QC Review

Graphical display of QC plot (histogram or Levey-Jennings) with Westgard Rules;

RealTime QC;

QCC PowerPak™ efficiency package

User Interface/Data Management

Monitor

17-inch touchscreen with adjustable height

Operating System

LINUX, 1 GB RAM

System Documentation

Operator manual, Quick Guide, and Online Help

Data Storage

120,000 patient tests (20 MB);

120,000 QC results (20 MB);

9000 calibrations (5 years, 18 MB)

Auto-System Check

User-defined time of day

Host Interface

RS-232C bidirectional

Host Query

System requests work order or batch of work orders from host

Remote Access and Service

Dimension Remote Services and Smart Remote Services via 1000BASE-T Ethernet port

General Specifications

Power Requirements System

100 VAC at 50/60 Hz, 13.5 amps max;

115 VAC at 60 Hz, 11 amps max;

230 VAC at 50 Hz, 5.5 amps max;

1.9 kW max power consumption

Water Specifications

• Instrument feed pressurized water source <3.8 bar (<55 psi)

• Instrument feed water system must maintain stable DO2 content between 5 and 8 ppm

• Temperature: <35°C (<95°F)

• Resistivity: >10 megohms cm

• Bacterial content: <10 colony forming units/mL

• System feed water line must not exceed 3 m (12 feet)

Water System

• Instrument may be supplied with a water purifier that provides instrument feed water

• If an alternative water system is used, water must adhere to Siemens water specifications

Maximum Water Consumption

5.0 L/hr (1.32 gal/hr)

Minimum Drain Requirements

5.0 L/hr (1.32 gal/hr)

Dimensions

143 cm W x 124 cm H x 104 cm D (56 in W x 49 in H x 41 in D) including LOCI module

Weight

358 kg (788 lb)

Compliance

Complies with international environmental, health, and safety standards including CE and RoHS

Noise Emission

<75 dB at 1 m while operating

Average Heat Output

1,100 W/hr (3753 BTU/hr)

Operating Temperature Range

18–30ºC (64–86ºF)

Ambient Humidity

20–80% (noncondensing)

Operating Altitude

Maximum 2000 m (6562 feet)

Pollution Classification

Degree 2

Removable Media

USB

Why Choose Us

We believe that success is achieved with professionalism, integrity and perfect teamwork, built on the high moral values of our employees.
Our policy is based on impeccable planning, control and execution, through which we achieve maximum satisfaction of our customers.

Professional
customer service

A wide range of laboratory analyzers

Trained and experienced specialists

Certificate
ISO 13485:2012